User's Manual
Siemens PLT 111 · 1999
3/22
Automation systems
Ordering data for ES 100 K
ES 100 K
Housing
The ES 100 K extension system is installed in a sheet-steel hous-
ing with degree of protection IP 21. This corresponds to a stan-
dard ordering configuration:
• Sheet-steel housing, degree of
protection IP 21 C79451-A3260-A50
Dimensions (HxWxD)
820 mm x 600 mm x 360 mm,
without heat exchanger, with
– separate ventilation roof,
– top panel with ventilation slits,
– front door, 600 mm wide, with lock,
– base with screwed-in cable panel,
175 mm deep, front half with ventilation slits
When using the supplied parts set for wall mounting, the dimen-
sions are increased as shown in Fig. 3/10.
Also refer to the ordering instructions in the appendix (page 8/2) with
information on ordering complete systems and options.
15
820
760
15 U
600 x 360
630
Æ 10.2
Ventilation roof
40
29 702
1 U = 44.5 mm
Fig. 3/10 ES 100 K extension system, design
Ordering data
ES 100 K options Order No.
ES 100 K extension
system
6DS2 103 -
Basic system
• Extension system AC 230 V 1 X X 0
• Extension system DC 24 V 2 X X 0
Housing
• Without housing 0
• Sheet-steel housing, degree of
protection IP 21, without heat
exchanger
1
O
r
d
er
N
o.
Connection of the 1st of max. four ES 100 K systems
of a link to
- I/O bus 1(A), address range 0 to 60, or
- I/O bus 2(B), address rang e 100 to 160
2 interface modules for ES 100 K
extension system
Can be inserted in slot for
I/O modules in the AS 235 and
ES 100 K
6DS1 322-8AA
Cable for signal transmission
(max. length Length 25 m
of a link: 5 m
500 m) 50 m
100 m
500 m
Intermediate lengths
6ES5 721-0BC50
6ES5 721-0BF00
6ES5 721-0CF00
6ES5 721-0DB00
6ES5 721-0DF00
See Catalog ST 50
Cable terminating plug
Can be inserted in interface mod-
ule for ES 100 K, required with last
extension system of a link
6ES5 760-1AA11
In addition when using the
address range 100 to 160:
Interface module for I/O bus 2 6DS1 312-8BB
Connection of 2nd to 4th ES 100 K system
of a link
Required per ES 100 K system:
Interface module for ES 100 K
extension system
Can be plugged in slot for I/O
modules of ES 100 K
6DS1 322-8AA
Cable for signal transmission
See above
Installation of ES 100 K in standard cabinet if
cabinet messages are to be detected
Alarm logic module
6DS1 901-8AA
System documentation
Instruction Manual “ES 100 K
extension system”
1)
– German
– English
1) Only order separately if the ES 100 K system is not ordered together
with an AS 235 K system.
C79000-B8000-C124
C79000-B8076-C124