User's Manual

Siemens PLT 111 · 1999
3/14
Automation systems
Ordering data for basic cabinet
AS 235 H
Ordering data
AS 235 automation system,
basic cabinet
6DS2 131- -
Basic unit
• Without basic unit 0
• Basic unit 4 Mbyte, with
I/O bus 1, redundant design
7
• Basic unit 4 Mbyte, with
I/O bus 1, non-redundant
design
8
Standard I/O devices
• Without standard I/O devices X
• Operation channel 1 with pro-
cess operation and configuring
keyboards, for redundant basic
unit
– Without process monitor
– With process monitor
A
M
• Operation channels 1 and 2:
2 process operation keyboards
and configuring keyboard, for
redundant basic unit
– Without process monitors
– With 2 process monitors
C
N
• Operation channel 1 with pro-
cess operation and configuring
keyboards, for non-redundant
basic unit
– Without process monitor
– With process monitor
E
P
• Operation channels 1 and 2,
2 process operation keyboards
and configuring keyboard, for
non-redundant basic unit
– Without process monitors
– With 2 process monitors
G
Q
Option:
extension units
• Without extension unit X
• Extension unit EE1,
wire-wrap system
A
• Extension unit EE1,
Maxi-Termi-Point system
B
• Extension units EE1 and EE2,
wire-wrap system
C
• Extension units EE1 and EE2,
Maxi-Termi-Point system
D
• Extension units EE1, EE2 and
EE3, wire-wrap system
E
• Extension units EE1, EE2 and
EE3, Maxi-Termi-Point system
F
Also refer to the ordering instructions in the appendix (page 8/2) with
information on ordering complete systems and options.
O
r
d
er
N
o.
Ordering data
AS 235 H automation system,
basic cabinet
6DS2 131- -
Option: power supply and bus
components
• Without components 0
• Power supply unit DC 24 V,
for redundant or non-redundant
basic unit
1
• Power supply unit DC 24 V
and connection unit for
remote bus,
for redundant basic unit
2
• Power supply unit DC 24 V
and connection unit
for redundant
remote bus,
for redundant basic unit
3
• Power supply unit DC 24 V
and connection unit for
remote bus,
for non-redundant basic unit
4
• Power supply unit DC 24 V
and connection unit
for redundant
remote bus,
for non-redundant basic unit
5
Option:
system cabinets
• Standard cabinet, degree of
protection IP 20, 400 mm deep,
without heat exchanger
1
• Standard cabinet, degree of
protection IP 54, 600 mm deep,
with heat exchanger
2
• Standard cabinet, degree of
protection IP 20, 600 mm deep,
without heat exchanger
3
Option:
system documentation
• Without system documentation 0 X
• German documentation 0 D
• English documentation 0 E
r
er
o.
This catalog is out of date, see note on page 1