User's Manual
Siemens PLT 111 · 1999
3/7
Automation systems
AS 235
Options for basic cabinet
Ordering data Order No.
Options for AS 235 basic
cabinet
Basic unit
Backup battery for memory
module
W79084-U1001-B2
Interface module for
I/O bus 2
6DS1 312-8BB
Extension units
For retrofitting of extension units
EE2 and EE3:
Subrack for extension unit
with mounting parts and slots for
14 I/O modules
• Wire-wrap system 6DS9 002-8BB
• Maxi-Termi-Point system
6DS9 002-8BA
Accessories for EE2:
Cable set for power supply of
EE2
6DS9 908-8CC
Cable set for I/O bus
6DS9 911-8FB
Cable duct
6DS9 906-8AB
Cover
6DS9 906-8BB
Accessories for EE3:
Cable set for power supply of
EE3
6DS9 908-8CD
Cable set for I/O bus
6DS9 911-8FC
Cable duct
6DS9 906-8AB
Cover
6DS9 906-8BB
Bus connection of further
participants via 20-m local bus
Interface module for 20-m local
bus N-V.24
1)
1) Max. 2 within an AS 235 consisting of basic and extension cabinets;
cannot be used in ES 100 K.
6DS1 202-8AB
With standard configuration with-
out remote bus connection:
Interface module for 20-m local
bus N-AS
6DS1 223-8AC
Connecting cable for local bus
with 1 plug 0.3 m
0.5 m
1.5 m
5.0 m
6DS8 201-8MB
6DS8 201-8SB
6DS8 201-8EC
6DS8 201-8SC
Front plug
2)
2) The cable connector 6DS8 205-8.. with 2 plugs can be used as an
alternative to the combination of connecting cable and front plug
6DS9 200-8AA
With standard configuration with
remote bus connection:
Connecting cable for local bus
with 1 plug
6DS8 201-8.. (see above)
Connection to single
remote bus
Bus converter UI 6DS4 400-8AB
Connector board AF “Remote
bus”
6DS9 203-8DA
Interface module for 20-m local
bus N-AS
6DS1 223-8AC
Connecting cable with 3 plugs
3)
to connect N-AS to bus
converter 1
3) 3rd plug not used, or on connection distributor
6DS8 204-8LC
Ordering data Order No.
Connection to redundant
remote bus
With standard configurations
6DS2 124-...2.
Bus converter UI 6DS4 400-8AB
Connector board AF “Remote
bus”
6DS9 203-8DA
With standard configurations
6DS2 124-...1.
2 bus converters UI 6DS4 400-8AB
2 connector boards AF “Remote
bus”
6DS9 203-8DA
Interface module for 20-m local
bus N-AS
6DS1 223-8AC
Connecting cable with 4 plugs
to connect N-AS to bus converters
1 and 2 and the connection dis-
tributor for 20-m local bus
6DS9 201-8CA
Remote bus cable
See page 6/6
Redundant supply of
L+
and
M
Supply diode 80 A C74103-A1900-A351
Parts set for redundant power
supply
with 2 cabinet power supply termi-
nals, capacitor and cable set
C79165-A3012-D74
Option:
system cabinets
Fan subassembly DC 24 V
(complete)
Installation kit/retrofitting kit for
AS 235 basic cabinet
• For installation below the basic
unit (initial use)
C79165-A3012-D201
• For installation below the basic
unit (retrofitting)
with power distribution subrack
6DS4 407-8CA with
– Version 1
– Version 2
C79165-A3012-D220
C79165-A3012-D221
• For installation below the exten-
sion unit
C79165-A3012-D206
Further cabinet accessories
See page 3/23
Partskitforupgradingthe
degree of protection of a
400-mm deep standard cabinet
from IP 10 to IP 20 (for former
cabinets)
C79165-A3012-D90
This catalog is out of date, see note on page 1