ASIMON V3 - Configuration software for AS-Interface safety monitor
20 Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02
On the Information bus tab, you must enter the AS-Interface bus addresses of the used stan-
dard slave and the safety-oriented AS-Interface slaves which are present in this AS-Interface
network.
Figure 3-4 Information about monitor and bus window, Information bus tab
With the Find button, you can also search the AS-Interface bus for slaves when the AS-Inter-
face safety monitor is in configuration operation.
If you clicked the Simulate slaves checkbox on the Diagnosis / Service tab, two or four bus
addresses are automatically assigned for the simulated slaves and the corresponding check-
box deactivated. In order to be able to activate Simulate slaves, the one or three addresses
which follow the monitor address must be free.
Notice
If you would like to operate two or more AS-Interface safety monitors on the same AS-Interface
bus, you must enter for all AS-Interface safety monitors all safe slaves on this AS-Interface bus
in the Information bus tab even when they are not monitored by the given AS-Interface safety
monitor.
Note
The AS-Interface slaves found when searching the AS-Interface bus are first all listed in the
Information bus tab as standard. You must then manually assign each as safe/standard!