Installation guide
Technical data 
8 
Siemens Building Technologies   
Fire Safety & Security Products    09.2008
3 Technical data 
3.1 Specifications 
Nominal Voltage 
CHSL4010:  110 – 230 V AC, 50/60 Hz 
CHSL4011:  12 – 24 V AC, 50/60 Hz 
Fuse Rating (Fuse F1) 
CHSL4010:  2 A 250 V AC 5 x 20 Type (T), HBC 
CHSL4011:  5 A 250 V AC 5 x 20 Type (T), HBC 
Electrical Connections 
Main supply connections via fused PCB mounted terminal blocks. 
Use crimped ferrules when terminating cables. 
6 way pillar terminal block available for user connections. 
Cable Entry 
1 x 25 mm hole to accept conduit (fitted with blanking plug). 
1 x 16 mm Cable Gland 
(5 – 10 mm diameter cable range) 
2 x 20 mm Cable Glands 
(6 – 12 mm diameter cable range) 
Heater  7 W nominal, 25 W max. 
PTC resistor heating element, thermostatically controlled. 
Environmental 
Operating Temperature  -20 to +60 °C (-20 to +40 °C when wiper kit fitted) 
Ensure fitted equipment has suitable temperature range for the 
application (e.g. maximum typical ambient operating temperature of 
camera and lens. Ta = 40 °C). 
Maximum internal dissipated power  50 W (25 W (including wiper motor) when wiper kit fitted) 
Relative humidity  Up to 95 % non-condensing 
Weatherproof rating  IP66, BS EN 60 529 
Material Toughened Glass Window 
Aluminium extrusions (Housing body / Sunshield) 
Die cast aluminium (front and rear end caps) 
Finish  Endcaps: Polyester powder coat, RAL7016 Grey 
Housing Body: Polyester powder coat, RAL9006 White Aluminium 
Sunshield: Polyester powder coat, RAL9006 White Aluminium 
Internal Dimensions (L x W x H)  400 x 125 x 110 mm 
Usable Height with Wiper fitted  88 mm 
Weight  Including Sunshield: 6.0 Kg 
  Excluding Sunshield: 4.9 Kg 
Suitable Pan and Tilt Units  CDD2425, CDD2416-T, CDAP2316-T, CDAP2416-T 
Suitable Brackets  CHBS2815, CDBS4540 + CAHA1040 