Technical data

60
Siemens Building Technologies
Fire Safety & Security Products 08.2006
12.4 Use with Bewator controllers
The following Bewator (Molynx) protocols are implemented and may be selected
from the PROTOCOL menu:
z Molynx
z Molynx V3
z PCCON
z PCCON 1-Way
12.4.1 Molynx & Molynx V3
NOTE
We recommend following interfacing:
z RS485 connection; 9600 baud, even parity, 8 data bits, 1 stop bit.
z Camera addressing is 0-511 for cameras 1-512. Also responds to broadcast addresses.
Tested using Bewator 600-Series, 6000-Series, Visilynx 2, Visilynx 2+, Visilynx V3i.
Operation User action Notes
Pan / Tilt / Zoom / Focus Joystick for pan/tilt;[ZOOM IN] / [ZOOM
OUT] for zoom; [FOCUS NEAR] /
[FOCUS FAR] for focus
When in OSD cursor mode Pan / Tilt operate as cursor right /
left / up / down (but see also Recall Preset 1 below).NB: on a
Visilynx 2 when in the CAMERA SETUP menu on the
keyboard it is not possible to control the camera's pan/tilt; it is
necessary to exit this keyboard menu to do so.
Iris [IRIS OPEN] / [IRIS CLOSE] Only operates when exposure priority is set to KEYBOARD.
AutoIris [AUTOIRIS] Overrides manual iris operation
AutoFocus Off / On [AUTOFOCUS ] Toggle action. Not available on 600-Series keyboard.
Day Mode / Night Mode [LAMPS] Toggle action. Switches camera between day and night
modes (colour/mono version only).
One-Touch White Balance [IRIS OPEN] If one-touch white balance is enabled in OSD and exposure
priority is not set to KEYBOARD.
Recall Preset [n] [PRESET RECALL] Range 1-99. Preset 95* or Preset 2* twice within 2 seconds
functions as the OSD Mode 'MENU' command. When in OSD
mode Preset 1 switches the joystick between cursor and
camera control. When in OSD cursor mode Preset 3 functions
as SET.
Store Preset [n] [PRESET PROGRAM] or [PROGRAM
KEY] [n] [PRESET] depending on
controller
Range 1-99.
Run Preset Sequence [PRESET SEQUENCE] Not available on 6000-Series keyboard.
Program Preset Sequence Save from sequence edit mode on
keyboard.
Action varies depending on keyboard.
Run Preset Tour [PRESET TOUR] Not available on 600-Series keyboard.
Program Preset Tour Save from tour edit mode on keyboard. Action varies depending on keyboard. Preset list for tour is the
same as that for the preset sequence.
Run Pattern [n] [PRESET TOUR] n can be 1, 2 or 3. Not available on 6000-Series keyboard.
Operate Relay [AUX1] Toggle action. Not available if any alarms are programmed to
operate the relay.
Enter OSD menu mode [MENU] On a 6000-Series keyboard the
[GLOBAL ON] key is used.
Recall Preset 95* or Recall Preset 2* twice within 2 s also
operates as the Menu function.
OSD menu navigation [SET], [UP], [DOWN], [LEFT], [RIGHT].
On a 6000-Series keyboard the keys are:
[GLOBAL OFF]
[PAUSE]
[MULTISCREEN]
[REWIND]
[FAST FWD]
If OSD menu mode was entered using Recall Preset 95*
(or Recall Preset 2* twice within 2 s) Recall Preset 3 will also
operate as the Set function and the joystick will operate as
Up, Down, Left and Right (the joystick can be switched
between cursor movement and camera control by Recall
Preset 1).