Technical data
59
Siemens Building Technologies
Fire Safety & Security Products 08.2006
Record / Recall Pattern 2 88 Mem / Pos Starts recording or playing Pattern 2.
Record / Recall Pattern 3 89 Mem / Pos Starts recording or playing Pattern 3.
Record / Recall Pattern 4 90 Mem / Pos Starts recording or playing Pattern 4.
Stop Pattern Record 91 Pos Stops recording current pattern.
12.3.2 Control via SIMATRIX NEO and dome converter CAC0103
The Siemens Solaris™ Dome can be controlled via the SIMATRIX video matrices.
SIMATRIX NEO provides direct physical connection via telemetry port 1. For
connection with SIMATRIX SYS / 648 / 164 an additional dome converter
CAC0103, Release V1.7 (Aug. 06) is required to interface the RS485 port of the
dome to the TTY port of the video matrix and to perform the necessary code
translation.
NOTE
We recommend following interfacing:
z RS485 connection, 9600 baud, even parity, 8 data bits, 1 stop bit,
z camera addressing is 0-254.
Tested using Siemens keyboard CKA4820 and SIMATRIX NEO , CAC0103
Operation User keyboard action Notes
Pan Left (var. speed) Pan Left
Pan Right (var. speed) Pan Right
Tilt Up (var. speed) Tilt Up
Tilt Down (var. speed) Tilt Down
Focus Near Focus Near
Focus Far Focus Far
Zoom In Zoom In
Zoom Out Zoom Out
Store Preset 1-64 [1…64] Mem
Recall Preset 1-64 [1…64] Pos
Enter OSD menu 65 Pos
Exit OSD 66 Pos
Go to Home Position 67 Pos Home position is Preset 1 on Solaris™.
Flip 68 Pos
Start Auto Patrol 69 Pos Start Preset Tour.
BLC On 70 Pos
BLC Off 71 Pos
One Push White Balance 72 Pos
One Push AutoFocus 73 Pos
Display Version 74 Pos Displays Dome and XTU firmware versions.
Setup privacy zone 76 Mem
IR CutFilter On ("Night Mode") 77 Pos
IR Cut Filter Off ("Day Mode") 78 Pos
Stop Scan 83 Pos Stops current sequence / tour / pattern.
Random Scan 84 Pos Starts random preset tour.
Frame Scan 85 Pos Starts preset sequence (fixed speed, uniform dwell time).
Auto Scan 86 Pos Starts preset tour.
Record / Recall Pattern 1 87 Mem / Pos Starts recording or playing Pattern 1.
Record / Recall Pattern 2 88 Mem / Pos Starts recording or playing Pattern 2.
Record / Recall Pattern 3 89 Mem / Pos Starts recording or playing Pattern 3.
Record / Recall Pattern 4 90 Mem / Pos Starts recording or playing Pattern 4.
Stop Pattern Record 91 Pos Stops recording current pattern.