Technical data
55
Siemens Building Technologies
Fire Safety & Security Products 08.2006
12 Telemetry controller operation and setup
This chapter explains how to operate the Solaris™ Dome using a telemetry
controller and describes:
z Accessing the OSD (Siemens, Molynx 6000, V3i and 3rd party)
z Protocol tables
12.1 Telemetry keyboard operation
A great deal of the configuration and set up of the Solaris™ Dome must be carried
out using the on-screen menu system that is described in Section 11: Configuration
of the Dome unit.
12.1.1 Access to the OSD with Siemens controllers
CKA4820/CKA3210 series controllers
Ensure that the telemetry control port of the CKA keyboard (Com-Port 2) is set to
“CCDA-protocol”. Use the following keys to navigate the Dome OSD menu:
Key Function
65 Pos or Cam + F1 Menu On
66 Pos or Cam + F10 Menu Off
Tilt Up Up
Tilt Down Down
Pan Left Left
Pan Right Right
Focus Far Select parameter / submenu
Focus Near Deselect parameter / exit submenu
1 Pos Toggle between OSD and PTZ navigation (function only available
when opening OSD via “65 Pos”)
NOTE
When opening the OSD with Cam + F1 it is necessary to exit the OSD with Cam + F10. It is possible
to exit the OSD menu by selecting the EXIT option in the OSD main menu. If so, the keyboard will
remain in menu mode (green LED flashing). It is necessary to use Cam + F10 to exit menu mode on
the keyboard in that case. Also Solaris™ will automatically exit the OSD mode after approx. 2 minutes
of no activity. In this case it is as well necessary to use Cam + F10 to exit menu mode on the
keyboard. When opening OSD with Cam + F1, toggling between OSD navigation and PTZ navigation
is not possible.
SIMATRIX NEO and SIMATRIX SYS/648/164 via dome converter CAC0103
Key Function
65 Pos or button OSD Menu On
66 Pos Menu Off
Tilt Up or button UP Up
Tilt Down or button DOWN Down
Pan Left Left
Pan Right Right
Focus Far or button SET Select parameter / submenu
Focus Near Deselect parameter / exit submenu
1 Pos Toggle between OSD and PTZ navigation