Technical data
10
Siemens Building Technologies
Fire Safety & Security Products 08.2006
4 Technical data
4.1 Dome
Electrical
Camera types 18x optical Colour (PAL): CCDS1415-ST
18x optical Day/Night (PAL): CCDS1415-DN
26x optical Day/Night (PAL): CCDS1415-DNX
Input voltage XTU 110 – 230 V AC @ 50 / 60 Hz, 1 A max.
In-rush current XTU 40 A / 20 A peak @ 110 / 230 V AC
Input voltage Dome unit 18-24 V DC @ 2 amp, supplied from the XTU via the
Cat-5 cable
Connections Video: BNC coax
Power: Screw terminal block
Telemetry: C type(Coax): BNC
D type (Twisted Pair): Screw terminal block
Alarm: Screw terminal block
Relay: Screw terminal block
Photon: Screw terminal block
Electromagnetic
compatibility
Compliant with EMC directive 89/336/EC.
Conforms to Part 15 of the FCC Rules, Class A digital
device
Operational
Pan speed 0.2-360°/sec
Pan travel 360° continuous
Tilt speed 0.2-360°/sec
Tilt travel +10° and -100°
Presets 99
Tours 32 positions, fully programmable for sequence, dwell and
speed
Preset accuracy 0.3°
Control hardware SIMATRIX NEO, SIMATRIX SYS/648/164 via CAC0103,
CKA3210, CKA4820, SISTORE AX, CX, MX, SX,
Visilynx V3i, Visilynx II, Visilynx 2+, 6000 series, 600
series,
XTU video output Nominal (no gain) VBS 1.0 Vp-p (sync negative)
Relay contact rating 1.5 A @ 24 V DC
Alarm input Opto-coupled (short to alarm com.)
Mechanical
Application Indoor or outdoor - all models
Mounting Wall/fixed ceiling, corner, wall top, pendant, pole, swan
neck or ceiling tile
Pendant mount size/thread Standard 1.5” BSP (parallel)
Weight Boxed 5.6 kg, XTU only (no cables) 1.5 kg, DOME UNIT
only (no cables) 2.5 kg
Ext. construction Injection moulded polycarbonate (GE Lexan EXL9335)
Colour Pure white RAL9010
Bubble Smoked: CCDS1415-ST
Clear:CCDS1415-DN / -DNX