Instruction manual
Installing the
 Camera 
16
Siemens Building Technologies
Fire Safety & Security Products    03.2005
7.2.4  EXPOSURE 
Fig. 4  EXPOSURE 
This function sets ALC for Auto IRIS lens control or ELC for auto electronic shutter. 
Move the cursor to the position shown in Fig. 4. The exposure level can be 
adjusted by moving the LEVEL cursor on the menu accordingly.
ALC
: 
ELC: Auto electronic shutter mode. 
NOTE: 
ELC mode is for use with fixed-iris lenses! 
7.2.5  SHUTTER 
Fig. 5  SHUTTER 
This function sets the high-speed electronic shutter (AUTO to 1/100K sec). 
Move the cursor to the position shown in Fig. 5. 
Using the LEFT/ RIGHT button, select a shutter speed from 1/50 to 1/100K. 
ALC MENU 
LENS TYPE DC 
LENS LEVEL ----------*----- 
BACK 
ELC MENU 
LENS LEVEL ----------*----- 
BACK 
D/N MODE AUTO 
D/N LEVEL HIGH 
D/N DELAY 15 sec 
EXPOSURE <ALC> 
SHUTTER 1/50 
GAIN NORMAL 
SYNC LL:000 
BLC OFF 
NEXT EXIT CANCEL DEFAULT 
D/N MODE AUTO 
D/N LEVEL HIGH 
D/N DELAY 15 sec 
EXPOSURE <ALC> 
SHUTTER 1/50 
GAIN NORMAL 
SYNC LL:000 
BLC OFF 
NEXT EXIT CANCEL DEFAULT 