4.10 Specify simulation settings
CamTool
Configuration Manual, 12.2004, 6AU1900-1AB32-0BA0
4-37
Field/button Explanation/instructions
Master velocity for calculations
(Setting (axis))
(Setting: None)
Gear ratio (relative) If you activate this option, all calculations are based on
relative values (values relative to the master axis).
Use standard velocity
(Setting (axis))
If you activate this option, the configured standard velocity
of the axis which you specified under Accept from axis is
accepted. All calculations are based on absolute values.
User-defined If you activate this option, you must enter a velocity under
V master. All calculations are based on absolute values.
V Master
(User-defined activated)
If you activate user-defined, you must enter the master
velocity under V master.
Slave tab
You specify here the simulation settings for the Slave tab.
You can set the following parameters:
Table 4-8 Parameters in the Slave tab (Simulation Settings window)
Field/button Explanation/instructions
Setting
Accept from axis
• (Axis)
When you create the cam for an axis that already exists
in the project, you can select the axis here. The
configured values are taken over and displayed.
• None
If you select None, you can specify all parameters.
Properties
(Setting: None)
Linear axis If you select this option, you simulate the slave axis as a
linear axis.
Rotary axis If you select this option, you simulate the slave axis as a
rotary axis.
Modulo rotary axis If you select this option, you simulate the slave axis as a
modulo rotary axis.
Type Here you select the axis type.
Unit of measure Here you specify the unit of measure for the axis. Select a
unit of measure or enter the unit of measure. The
representation of the unit of measure is refreshed in the
diagrams when you click Accept or OK.
Note:
The unit of measure is only used for the display. If the unit
of measure is changed, the represented values are not
converted.