7. List of Programming Commands – Control SMS Messages
Description
Command XXpppp
*1)
Range Set
Set PIN
PINVnnnn
nnnn 4 digits of PIN 0000
RESET of GSM Supervision RESET – –
Initialisation of parameters INIT – –
Regular information calling
ICALLVn
n= max. 14 digits –
Length of interval of calling
ICALLINTVh
h= 1–240 (hours) 168
Monthly calling
MCALLVn
n= max. 14 digits –
Alarm calling
ACALLiVn
n= max. 14 digits –
Information number
INFOSMSVn
n= max. 14 digits –
Interval of sending information
SMS messages
SMSINTVn
n= 1–255 (days) 7
Alarm SMS messages
SMSTXT1V“text”
SMSTXT2V“text”
SMSTXT3V“text”
SMSTXT4V“text”
SMSTXT5V “text”
SMSTXT6V “text”
SMSTXT7V“text”
SMSTXT8V“text”
text of 4–144 digits put in
“ ”
ALARM1
ALARM2
ALARM3
ALARM4
ALARM5
ALARM6
ALARM7
ALARM8
Numbers for
sending
ALARM SMS
messages
IO1 SMS n A
IO1 SMS n B
IO2 SMS n A
IO2 SMS n B
IO3 SMS n A
IO3 SMS n B
IO4 SMS n A
IO4 SMS n B
IO5 SMS n A
IO5 SMS n B
IO6 SMS n A
IO6 SMS n B
IO7 SMS n A
IO7 SMS n B
IO8 SMS n A
IO8 SMS n B
SMSNOA1Vn
SMSNOB1Vn
SMSNOA2Vn
SMSNOB2Vn
SMSNOA3Vn
SMSNOB3Vn
SMSNOA4Vn
SMSNOB4Vn
SMSNOA5Vn
SMSNOB5Vn
SMSNOA6Vn
SMSNOB6Vn
SMSNOA7Vn
SMSNOB7Vn
SMSNOA8Vn
SMSNOB8Vn
n= max. 14 digits –
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Set output No.1 (terminal No.1)
Set output No.2 (terminal No.2)
Set output No.3 (terminal No.3)
Set output No.4 (terminal No.4)
Set output No.5 (terminal No.5)
Set output No.6 (terminal No.6)
Set output No.7 (terminal No.8)
Set output No.8 (terminal No.9)
OUT1Vy
OUT2Vy
OUT3Vy
OUT4Vy
OUT5Vy
OUT6Vy
OUT7Vy
OUT8Vy
y= 0 output in logical
value 0
y= 1 output in logical
value 1
without y – logical value
0
1
1
1
1
1
1
1
1
Find out set-up
LISTVn
n= input No. 1 to 8
Without n – returns
common set-up
–
Call with monitoring
CALLBACKVn
n= max. 14 digits
Without no. calls back
–
*1) Always start with text XXpppp, where “pppp” is PIN of GB 051