Temperature Measurement
SITRANS TS500
Temperature transmitters for mounting in the connection head
2
Overview
The following temperature transmitters are available for mount-
ing in the connection head:
SITRANS TH100
Programmable two-wire temperature transmitter (4 to 20 mA),
without electrical isolation, only for Pt100 resistance thermome-
ters.
SITRANS TH200
Programmable two-wire temperature transmitter (4 to 20 mA),
electrical isolation for resistance thermometers and thermocou-
ple elements.
SITRANS TH300
Two-wire temperature transmitter with HART communication
(4 to 20 mA), electrical isolation for resistance thermometers and
thermocouple elements.
SITRANS TH400
Temperature transmitter with PROFIBUS PA or FOUNDATION
Fieldbus connection, electrical isolation for resistance thermom-
eters and thermocouple elements.
Note:
SITRANS TH100/TH200/TH300/TH400 can be fitted instead of
the terminal block or in the high hinged cover. Additional fitting
only possible in high hinged cover.
If using intrinsically-safe temperature sensors any installed
temperature transmitters must also be intrinsically-safe.
Selection and Ordering Data
Detailed information on the transmitters can be found for the re-
spective products under "Transmitters for temperature“.
Transmitter to be fitted Order code
To order the sensor with a built-in
temperature transmitter, add "-Z" to
the Article No. of the sensor, and
supplement by the following Order
code:
SITRANS TH100, only for Pt100
• Without Ex T10
• EEx ia IIC and EEx n for zone 2
T11
•FM
T13
SITRANS TH200
• Without Ex T20
• EEx ia IIC and EEx n for zone 2 T21
• FM (IS, I, NI) T23
SITRANS TH300
• Without Ex T30
• EEx ia IIC und EEx n for zone 2
T31
• FM (IS, I, NI)
T33
SITRANS TH400 PA
• Without Ex T40
• EEx ia T41
SITRANS TH400 FF
• Without Ex T45
• EEx ia T46
• Customer-specific setting of the
built-in transmitter (specify set-
tings in plain text)
Y11