Specifications
2/8
Siemens FI 01 · 2015 US Edition
Temperature Measurement
Transmitters for mounting in sensor head
SITRANS TH200 two-wire system, universal
2
■
Overview
Ultra flexible - with the universal SITRANS TH200 transmitter
• Two-wire devices for 4 to 20 mA
• Mounting in the connection head of the temperature sensor
• Universal input for virtually any type of temperature sensor
• Configurable over PC
■
Benefits
• Compact design
• Flexible mounting and center hole allow you to select your pre-
ferred type of installation
• Electrically isolated
• Test sockets for multimeters
• Diagnostics LED (green/red)
• Sensor monitoring
open circuits and short-circuits
• Self-monitoring
• Configuration status stored in EEPROM
• SIL2 (with Order Code C20), SIL2/3 (with C23)
• Expanded diagnostic functions, such as slave pointer, operat-
ing hours counter, etc.
• Special characteristic
• Electromagnetic compatibility to EN 61326 and NE21
■
Application
SITRANS TH200 transmitters can be used in all industrial sec-
tors. Due to their compact size they can be installed in the con-
nection head type B (DIN 43729) or larger. The following sen-
sors/signal sources can be connected over their universal input
module:
• Resistance thermometers (2, 3 or 4-wire system)
• Thermocouples
• Resistance-based sensors and DC voltage sources
The output signal is a direct current from 4 to 20 mA in accor-
dance with the sensor characteristic.
Transmitters of the "intrinsically safe" type of protection can be in-
stalled within potentially explosive atmospheres. The devices
comply with the Directive 94/9/EC (ATEX), as well as FM and
CSA regulations.
■
Function
The SITRANS TH200 is configured over a PC. A USB or RS 232
modem is linked to the output terminals for this purpose. The
configuration data can now be edited using the SIPROM T soft-
ware tool. The configuration data are then permanently stored in
the non-volatile memory (EEPROM).
Once the sensors and power supply have been correctly con-
nected, the transmitter outputs a temperature-linear output sig-
nal and the diagnostics LED displays a green light. In the case
of a sensor short-circuit, the LED flashes red, an internal device
fault is indicated by a steady red light.
The test socket can be used to connect an ammeter at any time
for monitoring purposes and plausibility checks. The output cur-
rent can be read without any interruption, or even without open-
ing the current loop.
SITRANS TH200 function diagram
Input
A/D Analog-digital converter
Sensors Resistance thermometer, thermocouple,
resistance-based sensor, mV sensor
μC1 Microcontroller, secondary circuit
Output
μC2 Microcontroller, primary circuit
D/A Digital-analog converter
U
aux
Auxiliary power supply
I
out
Output current
(1) Electrically isolated
(2) LED
TC/RTD
sensor
(2)
+1
-2
(1)
µC1
µC2
Test
4 ... 20 mA U
aux
, I
out
SITRANS TH200/TH300
D
A
A
D
© Siemens AG 2015