Specifications

2/76
Siemens FI 01 · 2015 US Edition
Temperature Measurement
SITRANS TS500
Technical description
2
Design
SITRANS TS500 7MC65xx
SITRANS TS500, type SWR, socket reduced well, dimensions in mm (inch)
The temperature sensors of the SITRANS TS500 series are avail-
able in four different designs:
General Purpose without Thermowell
Threaded Thermowell
Flanged Thermowell
Socket Thermowell
Function
A complete measuring point consists of a measuring insert
which contains the basic sensors, the protective fitting and an
optional transmitter.
The basic sensors are:
Resistance thermometers:
Temperature measurement is based on the temperature de-
pendency of the installed measuring resistor.
Thermocouples:
Temperature measurement is based on the Seebeck effect.
A thermocouple which subjected to a temperature drop pro-
duces thermoelectric voltage that can be measured.
Transmitters:
The optional Siemens transmitters assume the following func-
tions:
Optimum measurement processing
Strengthening of weak sensor signals directly on site
Transmits standardized signals
Protects against electromagnetic interfrences
Support enhanced diagnosis options
The resistance thermometer is intended for installation in con-
tainers and pipelines.
Modular design consisting of protective pipe, measuring in-
sert, connection head and optional transmitter for replace-
ment during operation.
Transmitter can be integrated (4 to 20 mA, PROFIBUS PA or
FOUNDATION Fieldbus)
Ød
D8
ØD
6.35 (0.25)
12.7 (0.5)
95 (3.74)N
44.45 (1.75) X
U
6.604
(0.26)
Bore
63.5 (2.5)
© Siemens AG 2015