Specifications

2/55
Siemens FI 01 · 2015 US Edition
Temperature Measurement
Transmitters for field mounting
SITRANS TF280 WirelessHART
2
Integration of a meshed network into SIMATIC PCS 7
Configuration
Configuration of the SITRANS TF280 transmitter may be carried
out as follows:
Initial commissioning for the SITRANS TF280 with SIMATIC
PDM is generally carried out via a HART modem or the inte-
grated local user interface, since the network ID and join Key
must be set up on the device before it can be accepted and
integrated into the WirelessHART network.
Once it is integrated into the network, the device can be con-
veniently operated with the WirelessHART network or onsite
with a HART modem or via the local user interface.
Technical specifications
The SITRANS TF280 can be mechanically installed in two ways:
Direct at the measuring point with a M20x1.5 thread.
A connection to other threads can be done via the adapter.
Remotely from the Pt100 sensor, which is connected to the
transmitter via a cable.
The data in the following table refer to the transmitter only ex-
cluding a connected sensor, except as noted otherwise.
SIMATIC
system
SIMATIC ET 200
with HART support
ES OS MS
IE/WSN-
PA LINK
SITRANS
AW210
SITRANS
AW200
SITRANS
AW210
SITRANS
TF280
SITRANS
P280
DP/PA
LINK
Industrial Ethernet
PROFIBUS
Wireless
HART
PROFIBUS PA
Input
Sensor
• Sensor type Pt100 as per
IEC 751/DIN EN 60751
1)
• Connection Two, three or four-wire system
• Measuring range
-200 ... +850 °C (-328 ... 1560 °F)
Cable length SITRANS TF280 and
Pt100 sensor element
3m
Measuring accuracy
2)
Accuracy < 0.04 % of the measuring range
Long-term drift < 0.035 % of the measuring range
in first year
Ambient temperature effect max. 0.1 °C/10 K
Rated conditions
Ambient temperature -40...+8C (-40...+17F)
Storage temperature -40 ... +85 ° C (-40 ... +185 °F)
Relative humidity <95%
Climatic class 4K4H in accordance with
EN 60721-3-4
(stationary use at locations not pro-
tected against weather)
Degree of protection IP65/NEMA 4
Max. permissible temperature at
transmitter for directly mounted
Pt100
80 °C (176 °F)
Design
Enclosure Die-cast aluminum
Shock resistance
in accordance with
DIN EN 60068-2-29 / 03.95
Resistance to vibration
DIN EN 60068-2-6/12.07
Weight
• without battery 1.5 kg (3.3 lb)
• with battery 1.6 kg (3.5 lb)
Dimensions (W x H x D)
See "Dimensional drawing"
Thread for cable gland/
sensor connection
M20x1.5
other threads via adapter
Material of protective tubes and
process connection (only for pre-
mounted sensor pipe)
Stainless steel 1.4404 (AISI 316L,
UNS S 31603, X2CrNiMo17-12-2)
Cable between transmitter and
sensor element
3 m für two-, three- or four-wire
connections
Cable resistance < 1 (setting
range in m 0...9999)
Sensor break
Recognized
© Siemens AG 2015