Specifications

2/25
Siemens FI 01 · 2015 US Edition
Temperature Measurement
Transmitters for mounting in sensor head
SITRANS TH400 fieldbus transmitter
2
Selection and Ordering data
Article No.
Ordering example 1:
7NG3214-0NN00-Z Y01+Y17+U03
Y01: 0...100 °C
Y17: TICA1234HEAT
Ordering example 2:
7NG3214-0NN00-Z Y01+Y17+Y25+U25
Y01: 0...500 °C
Y17: TICA5678HEAT
Y25: 33
Factory setting:
For SITRANS TH400 PA:
- Pt100 (IEC 751) with 3-wire circuit
- Unit: °C
- Failure mode: Last valid value
- Filter time: 0 s
- PA address: 126
- PROFIBUS Ident No.: Manufacturer-specific
For SITRANS TH400 FF:
- Pt100 (IEC 751) with 3-wire circuit
- Unit: °C
- Failure mode: Last valid value
- Filter time: 0 s
- Node address: 22
Temperature transmitter SITRANS TH400
for installation in connection head, with
electrical isolation, order operating instruc-
tions separately.
• Bus-compatible to PROFIBUS PA
- No explosion protection or Zone 2/Div 2
to ATEX/FM/CSA/IECEX/NEPSI
7NG3214-0NN00
- With explosion protection "Intrinsically
safe to ATEX/FM/CSA/IECEX/NEPSI"
7NG3214-0AN00
• Bus-compatible to FOUNDATION Fieldbus
- No explosion protection or Zone 2/Div 2
to ATEX/FM/CSA/IECEX/NEPSI
7NG3215-0NN00
- With explosion protection "Intrinsically
safe to ATEX/FM/CSA/IECEX/NEPSI"
7NG3215-0AN00
Further designs
Order code
Please add "-Z" to Article No. and specify
Order code(s) and plain text.
With test protocol (5 measuring points) C11
Customer-specific programming
Add "-Z" to Article No. and specify Order
code(s)
Measuring range to be set
Specify in plain text (max. 5 digits):
Y01: ... to ... °C, °F
Y01
1)
Measuring point no. (TAG), max. 32 charac-
ters
Y17
2)
Measuring point descriptor, max. 32 charac-
ters
Y23
2)
Measuring point message, max. 32 charac-
ters
Y24
2)
Bus address, specify in plain text Y25
2)
Pt100 (IEC) 2-wire, R
L
= 0 U02
3)
Pt100 (IEC) 3-wire U03
3)
Pt100 (IEC) 4-wire U04
3)
Thermocouple type B U20
3)4)
Thermocouple type C (W5) U21
3)4)
Thermocouple type D (W3) U22
3)4)
Thermocouple type E U23
3)4)
Thermocouple type J U24
3)4)
Thermocouple type K U25
3)4)
Thermocouple type L U26
3)4)
Thermocouple type N U27
3)4)
Thermocouple type R U28
3)4)
Thermocouple type S U29
3)4)
Thermocouple type T U30
3)4)
Thermocouple type U U31
3)4)
With TC: CJC external (Pt100, 3-wire) U41
With TC: CJC external with fixed value, spe-
cify in plain text
Y50
Special differing customer-specific program-
ming, specify in plain text
Y09
5)
Accessories
Article No.
MiniDVD for temperature measuring
instruments
A5E00364512
With documentation in German, English,
French, Spanish, Italian, Portuguese and
SIPROM T parameterization software
SIMATIC PDM operating software See Chapter 8
DIN rail adapters for head transmitters 7NG3092-8KA
(Quantity delivered: 5 units)
Connecting cable
4-wire, 150 mm, for sensor connections
when using head transmitters in the high
hinged cover (set with 5 units)
7NG3092-8KC
for additional PA components
See Catalog IK PI
1)
For customer-specific programming for RTD and TC, the start value and
the end value of the required measuring span must be specified here.
2)
For this selection, Y01 or Y09 must also be selected.
3)
For this selection, Y01 must also be selected.
4)
Internal cold junction compensation is selected as the default for TC.
5)
For customer-specific programming, for example mV and ohm, the start
value and the end value of the required measuring span and the unit must
be entered here.
© Siemens AG 2015