Specifications

2/12
Siemens FI 01 · 2015 US Edition
Temperature Measurement
Transmitters for mounting in sensor head
SITRANS TH200 two-wire system, universal
2
Selection and Ordering data
Article No.
Supply units see Chapter "Supplementary Components".
Ordering example 1:
7NG3211-1NN00-Z Y01+Y17+U03
Y01: -10 ... +100 °C
Y17: TICA123
Ordering example 2:
7NG3211-1NN00-Z Y01+Y23+U25
Y01: -10 ... +100 °C
Y23: TICA1234HEAT
Factory setting:
Pt100 (IEC 751) with 3-wire circuit
Measuring range: 0 … 100 °C (32 … 212 °F)
Fault current: 22.8 mA
Sensor offset: 0 °C (0 °F)
Damping 0.0 s
Temperature transmitter SITRANS TH200
for installation in connection head, type B
(DIN 43729), two-wire system, 4 ... 20 mA,
programmable, with electrical isolation
• Without explosion protection 7NG3211-1NN00
• With explosion protection
-to ATEX 7NG3211-1AN00
- to FM (
c
FM
US
) 7NG3211-1BN00
Further designs Order code
Add "-Z" to Article No. and specify Order code(s)
With test protocol (5 measuring points) C11
Functional safety SIL2
C20
Functional safety SIL2/3 C23
Customer-specific programming
Add "-Z" to Article No. and specify Order code(s)
Measuring range to be set
Specify in plain text (max. 5 digits):
Y01: ... to ... °C, °F
Y01
1)
Measuring point no. (TAG), max. 8 characters Y17
2)
Measuring point descriptor, max. 16 charac-
ters
Y23
2)
Measuring point message, max. 32 characters Y24
2)
Pt100 (IEC) 2-wire, R
L
= 0 U02
3)
Pt100 (IEC) 3-wire U03
3)
Pt100 (IEC) 4-wire U04
3)
Thermocouple type B U20
3)4)
Thermocouple type C (W5) U21
3)4)
Thermocouple type D (W3) U22
3)4)
Thermocouple type E U23
3)4)
Thermocouple type J U24
3)4)
Thermocouple type K U25
3)4)
Thermocouple type L U26
3)4)
Thermocouple type N U27
3)4)
Thermocouple type R U28
3)4)
Thermocouple type S U29
3)4)
Thermocouple type T U30
3)4)
Thermocouple type U U31
3)4)
With TC: CJC external (Pt100, 3-wire) U41
With TC: CJC external with fixed value, specify
in plain text
Y50
Special differing customer-specific program-
ming, specify in plain text
Y09
5)
Fail-safe value 3.6 mA (instead of 22,8 mA) U36
2)
Cable extension
Transmitter with installed cable extension
200 mm (7.81 inch),
for Pt100 in four-wire system
W01
Accessories Article No.
Modem for SITRANS TH100, TH200, TR200
and TF with TH200 incl. SIPROM T parameteri-
zation software
With USB connection
7NG3092-8KU
MiniDVD for temperature measuring instru-
ments
With documentation in German, English,
French, Spanish, Italian, Portuguese and
SIPROM T parameterization software
A5E00364512
DIN rail adapters for head transmitters
(Quantity delivered: 5 units)
7NG3092-8KA
Connecting cable
4-wire, 150 mm, for sensor connections when
using head transmitters in the high hinged
cover (set with 5 units)
7NG3092-8KC
1)
For customer-specific programming for RTD and TC, the start value and
the end value of the required measuring span must be specified here.
2)
For this selection, Y01 or Y09 must also be selected.
3)
For this selection, Y01 must also be selected.
4)
Internal cold junction compensation is selected as the default for TC.
5)
For customer-specific programming, for example mV and ohm, the start
value and the end value of the required measuring span and the unit must
be entered here.
© Siemens AG 2015