Operating Instructions

Table Of Contents
Keypad of the drive Siemens Industry, Inc. • 9
24-hour support +1-800-877-7545 (Dial 2)
2
Figure 3. Editing values on graphical keypad.
2.1.2.2 Resetting fault
Instructions for how to reset a fault can be found in Chapter 3.7.1 on page 95.
2.1.2.3 Hand/Auto control button
The Hand/Auto button is used for two functions: to quickly access the Control page and to easily change
between the Hand (Keypad/Loc) and Auto control places.
Control places
The control place is the source of control where the drive can be started and stopped. Every control place
has its own parameter for selecting the frequency reference source. In the HVAC drive, the Hand control
place is always the keypad. The Auto control place is determined by parameter P1.15 (I/O or Fieldbus).
The selected control place can be seen on the status bar of the keypad.
Auto control place
I/O A, I/O B and Fieldbus can be used as Auto control places. I/O A and Fieldbus have the lowest priority
and can be chosen with parameter P3.2.1 (Ctrl. Place Auto). I/O B, again, can bypass the Auto control
place selected with parameter P3.2.1 using a digital input. The digital input is selected with parameter
P3.5.1.5
(I/O B Ctrl Force).
Hand control
The Keypad is always used as control place while in Hand control. Hand control has a higher priority
than the Auto control. Therefore, if, for example, bypassed by parameter P3.5.1.5 through digital input
while in Auto, the control place will still switch to Keypad if Hand is selected. Switching between Hand
and Auto Control can be done by pressing the HAND/AUTO button on the keypad or by using
the "Hand/Auto" (ID211) parameter.
Changing control places
Change of control place from Auto to Hand (keypad).
1. Anywhere in the menu structure, push the HAND/AUTO button.
2. Push the Arrow up or the Arrow down button to select HAND/AUTO and confirm with
the OK button.
3. On the next display, select Hand or Auto and again confirm with the OK button.
4. The display will return to the same location it was when the HAND/AUTO button was pushed.
However, if the Auto control place was changed to Hand (Keypad), you will be prompted for a
keypad reference.
STOP READY I/O
ID:172 M3.2.1
STOP READY I/O
ID: M3.2.1
STOP READY I/O
M3.2.1
STOP READY I/O
ID:172 M3.2.1
STOP READY I/O
M3.2.1
BT9160
BACK
RESET
OR:
Start/Stop Setup
Ctrl. Place Auto
I/O Control
KeypadStopButton
Yes
Start Function
Ramping
Edit
Help
Add to favorites
Ctrl. Place Auto Ctrl. Place Auto
I/O Control
FieldbusCTRL
Start/Stop Setup
Ctrl. Place Auto
I/O Control
KeypadStopButton
Yes
Start Function
Ramping
Ctrl. Place Auto
I/O Control
FieldbusCTRL