Operating Instructions
Table Of Contents
- 1. Siemens BT300 - Startup
- 2. Keypad of the drive
- 3. Siemens Application
- 3.1 Specific functions of the Siemens application
- 3.2 Example of control connections
- 3.3 Application - Quick setup parameter group
- 3.4 Monitor group
- 3.5 Application parameter lists
- 3.5.1 Parameter programming
- 3.5.2 Column explanations
- 3.5.3 Group 3.1: Motor settings
- 3.5.4 Group 3.2: Start/Stop setup
- 3.5.5 Group 3.3: Control reference settings
- 3.5.6 Group 3.4: Ramp & Brakes Setup
- 3.5.7 Group 3.5: I/O Configuration
- 3.5.8 Group 3.6: Fieldbus Data Mapping
- 3.5.9 Group 3.7: Prohibited Frequencies
- 3.5.10 Group 3.8: Limit supervisions
- 3.5.11 Group 3.9: Protections
- 3.5.12 Group 3.10: Automatic reset
- 3.5.13 Group 3.11: Timer functions
- 3.5.14 Group 3.12: PID-controller 1
- 3.5.15 Group 3.13: PID-controller 2
- 3.5.16 Group 3.14: Multi-pump
- 3.5.17 Group 3.16: Fire mode
- 3.5.18 Group 3.17: Application settings
- 3.6 HVAC Application - Additional parameter information
- 3.7 Application - Fault tracing
Siemens Industry, Inc. • 32 Siemens Application
24-hour support +1-800-877-7545 (Dial 2)
EXAMPLE:
You want to connect the Control signal 2 A (parameter P3.5.1.2) to digital input DI2 on Standard I/O
board.
3.5.1.1 Example programming with graphical keypad
1
Locate the parameter Control signal 2 A (P3.5.1.2) on the keypad.
2
Enter the Edit mode.
3
Change the value: The editable part of the value (DigIN Slot0) is underlined and blinking.
Change the slot to DigIN SlotA or assign the signal to Time Channel with the arrow keys
up and down. Make the terminal value (.1) editable by pressing the right key once and
change the value to ‘2’ with arrow keys up and down.
Accept the change with OK button or return to previous menu level with BACK/RESET
button.
STOP READY Keypad
(17)
(5)
ID: M3
(12)
STOP READY Keypad
(18)
(4)
(7)
ID: M3.5
STOP READY Keypad
(26)
(36)
(1)
ID: M3.5.1
STOP READY Keypad
DigIn Slot0.1
DigIn Slot0.1
DigIn SlotA.1
ID:404 M3.5.1.2
BT9149
Main Menu
Quick Setup
Monitor
Parameters
References
Parameters
I/O Config
Ramps and Brakes
I/O Config
Digital Inputs
Analog Inputs
Digital Outputs
Digital Inputs
Ctrl Signal 1 A
Ctrl Signal 2 A
Ctrl Signal 1 B
STOP READY Keypad
DigIn Slot0.1
DigIn Slot0.1
DigIn SlotA.1
ID:404 M3.5.1.2
STOP READY Keypad
ID: M3.5.1.2
STOP READY Keypad
Min:
Max:
ID:404 M3.5.1.2
BT9150
Digital Inputs
Ctrl Signal 1 A
Ctrl Signal 2 A
Ctrl Signal 1 B
Ctrlsignal2A
Edit
Help
Add to favorites
Ctrl signal 2 A
DigIN SlotA.2
DigIN Slot0
DigIN SlotA
DigIN SlotB
DigIN SlotC
DigIN SlotD
DigIN SlotE
TimeChannel
Fieldbus CW
LLP signal
0-10
Varies
Varies
Varies
Varies
Varies
1-3
0-31
1-5