Operating Instructions
Table Of Contents
- 1. Siemens BT300 - Startup
- 2. Keypad of the drive
- 3. Siemens Application
- 3.1 Specific functions of the Siemens application
- 3.2 Example of control connections
- 3.3 Application - Quick setup parameter group
- 3.4 Monitor group
- 3.5 Application parameter lists
- 3.5.1 Parameter programming
- 3.5.2 Column explanations
- 3.5.3 Group 3.1: Motor settings
- 3.5.4 Group 3.2: Start/Stop setup
- 3.5.5 Group 3.3: Control reference settings
- 3.5.6 Group 3.4: Ramp & Brakes Setup
- 3.5.7 Group 3.5: I/O Configuration
- 3.5.8 Group 3.6: Fieldbus Data Mapping
- 3.5.9 Group 3.7: Prohibited Frequencies
- 3.5.10 Group 3.8: Limit supervisions
- 3.5.11 Group 3.9: Protections
- 3.5.12 Group 3.10: Automatic reset
- 3.5.13 Group 3.11: Timer functions
- 3.5.14 Group 3.12: PID-controller 1
- 3.5.15 Group 3.13: PID-controller 2
- 3.5.16 Group 3.14: Multi-pump
- 3.5.17 Group 3.16: Fire mode
- 3.5.18 Group 3.17: Application settings
- 3.6 HVAC Application - Additional parameter information
- 3.7 Application - Fault tracing
Siemens Industry, Inc. • 96 Siemens Application
24-hour support +1-800-877-7545 (Dial 2)
3.7.3 Fault codes
Table 57. Fault codes and descriptions.
Fault
code
Fault
ID
Fault name Possible cause Remedy
1
1
Over-current
(hardware fault)
The drive has detected too high a current
(>4*I
H
) in the motor cable:
• sudden heavy load increase
• short circuit in motor cables
• unsuitable motor
Check loading.
Check motor.
Check cables and connections.
Make identification run.
Check ramp times.
2
Over-current
(software fault)
2
10
Over-voltage
(hardware fault)
The DC-link voltage has exceeded the
limits defined.
• too short a deceleration time
• high over-voltage spikes in supply
• Start/Stop sequence too fast
Make deceleration time longer.
Activate overvoltage controller.
Check input voltage.
11
Over-voltage
(software fault)
3
20
Earth fault (hard-
ware fault)
Current measurement has detected that
the sum of motor phase current is not
zero.
• insulation failure in cables or motor
Check motor cables and motor.
21
Earth fault (soft-
ware fault)
540Charging switch
The charging switch is open, when the
START command has been given.
• faulty operation
• component failure
Reset the fault and restart.
Should the fault re-occur, contact the
distributor near to you.
760Saturation
Various causes:
• defective component
• brake resistor short-circuit or over-
load
Cannot be reset from keypad.
Switch off power.
DO NOT RE-CONNECT POWER!
Contact factory.
If this fault appears simultaneously
with F1, check motor cables and
motor.