3.7 System monitoring
M200D AS-Interface Basic
34 Manual, 03/2009, A5E01668085-01
Description of the actions
Quick stop
The motor and brake output are shut down without a group fault.
"Quick stop" has priority over "Motor CW" and "Motor CCW".
The input action responds to the active edge of the input signal, which means that
deactivation is possible when the static input signal "Quick stop" is present.
The input trigger is reset when the "Motor CW"/"Motor CCW" control commands are
canceled or by means of "Disable quick stop" (in the process image).
Note
When bit DO2 (PIO) (Disable quick stop) is set, input 1 in the PII can be used as a free
input because the input function "Quick stop" is deactivated.
Example:
'2PRWRUULJKW
',LQSXW
4XLFNVWRSIXQFWLRQ
'2'LVDEOHTXLFNVWRS
0RWRU
Figure 3-4 Example: quick stop
Emergency start
Starts the motor when an ON command is issued despite the fact that an internal
shutdown command is present.
Switches on the brake output too if an ON command is present for this.
The self-protection function of the motor starter remains active and prevents the device
from being destroyed.
Tripping limit position CW/CCW
The motor and the brake output are tripped regardless of the direction of rotation.
The brake output can be switched on again once the "Brake" and "Motor CW / CCW"
control commands have been canceled.
Tripping limit position CW: The motor can only be switched on again with the opposite
command ("Motor CCW").
Tripping limit position CCW: The motor can only be switched on again with the opposite
command ("Motor CW").