User's Manual

Functions
3.7 System monitoring
M200D AS-Interface Basic
Manual, 03/2009, A5E01668085-01
33
Input n signal
The input level of the digital inputs is stored for inputs IN1 and IN2, that is, the active edge
executes the input action assigned to the corresponding input. Regardless of the input signal
present, the action can only be deactivated again by a further event.
The input level is not stored for inputs IN3 and IN4. This input action is active as long as the
input is active.
Input n level
The input logic for the M200D AS-i Basic is set to "NO contact".
Setting
Device parameter
.DS... .RS...
Input signal delay 10 ms 10 ms
Input 1 level
Input 2 level
Input 3 level
Input 4 level
NO contact NO contact
Input 1 action Quick stop Quick stop
Input 2 action No action No action
Input 3 action Emergency start Tripping limit position CW
Input 4 action Shutdown with restart Tripping limit position CCW
Input 1 signal Latching (edge evaluation) Latching (edge evaluation)
Input 2 signal
Input 3 signal
Input 4 signal
Unlatching (level evaluation) Unlatching (level evaluation)