User's Manual
Product family
2.2 Overview of the device functions
M200D AS-Interface Basic
14 Manual, 03/2009, A5E01668085-01
2.2 Overview of the device functions
Device functions Electromechanical (DSte, RSte)/
electronic (sDSte, sRSte)
Fieldbus interface ●
Control function: reversing starter ○
Control function: soft starter —
Brake output 400 V / 230 V AC ○
Brake output 180 V DC ○
Thermal motor model ●
Temperature sensor (thermistor motor protection) ●
Asymmetry monitoring ●
Blocking current monitoring ●
Zero-current monitoring ●
M12 inputs (routed via AS-i) 4 (2)
M12 outputs (routed via AS-i) 1 (0)
Connector monitoring ●
Short-circuit protection ●
Communication
Slave type A/B slave (4I / 3O)
Communication profile 7.A.E
Diagnostics via parameter channel (parameter echo) ●
Support for AS-i S1 status bit ●
Transfer of data sets via AS-i —
Extended cyclic process image —
Access via "Motor Starter ES" —
Additional functions
Self-test ●
Local device interface ●
Disconnecting means ●
Integrated manual local control
(key-operated switch, keypad with LEDs)
○
Setting elements parameterized on device ●
● Integrated
○ Order variant