Specifications
Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 57 of 83
Version 2 Status Released
Last Editor Harry Smyth Date 09/12/2014
Document Name Configuration Control Document No. 667/CC/45950/000
Copyright © Mobility 2014. All Rights Reserved. Mobility is a division of Siemens Plc
4.6 Manual Panel
The Manual Panel is contained within a secure compartment in the top left hand corner of
the controller cabinet. Access to the manual panel may be gained via the manual panel
access door or by opening the controller cabinet main door. The manual panel forms part of
the Outercase, chosen from Table 4, and therefore should not be specified separately. The
34 way ribbon cable from manual panel connects into socket manual panel connection on
the CPU Card.
Figure 41 – ST950 Manual Panel
4.7 Intelligent Detector Backplanes
Intelligent Detector Backplanes do not form part of the base Controller Cabinet and therefore
should be specified separately. Each Intelligent Detector accommodates four SDL4 Cards.
Notes on the SLD4 Detector Cards are provided later in this document. Figure 50 provides a
listing of required components when selecting the Intelligent Detector Backplanes and
accompanying SLD4 cards. Please also refer to the parts list for these items.
Optimising the positions of Intelligent Detector Backplanes within the ST950ELV is an
involved but necessary procedure. The four separate cases, detailed in Case 1 – 1
Intelligent Detector Cards (4 Loop detector cards) and a Gemini unit or Stratos Outstation
Figure 42 to 45, define the order of allocation for the Intelligent Detector Backplanes in the
6U Rack, and therefore the positioning of the Detector cards, which are detailed later in this
document. Connection of the twisted ribbon cable between detector loop termination cards
to appropriate intelligent detector backplane is also detailed in Case 1 – 1 Intelligent
Detector Cards (4 Loop detector cards) and a Gemini unit or Stratos Outstation
Figure 42 to 45.
In the following series of case studies it is necessary to install the appropriate Rack
Assembly dividers. Please consult the parts listing for these necessary dividers. Please note,
the position in the rack of the Intelligent Detector Backplanes depends on the number of loop
detector cards required.
Configuration Engineers should note when referencing the cases below that an infrared
communication link provides automatic set-up between SLD4 cards. This link operates
horizontally but not vertically. To provide this link between vertically mounted SLD4 cards a
link cable should be fitted between Intelligent Detector Backplanes on associated horizontal
levels. Please refer to parts listing for link cable. Please also refer to Figure 47 which shows
the required link.