Specifications

Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 18 of 83
Version 2 Status Released
Last Editor Harry Smyth Date 09/12/2014
Document Name Configuration Control Document No. 667/CC/45950/000
Copyright © Mobility 2014. All Rights Reserved. Mobility is a division of Siemens Plc
Table 2 – Serial Link Connections
Component Input Output
CPU card Serial link derived from
CPU card
RJ45 Serial Link Output
Socket
CPU I/O Card RJ45 Serial Link Input RJ45 Serial Link Output
Termination Panel Upper
I/O Card
RJ45 Serial Link Input RJ45 Serial Link Output
Termination Panel Lower
I/O Card
RJ45 Serial Link Input RJ45 Serial Link Output
First Intelligent Detector
Backplane
RJ45 Serial Link Input RJ45 Serial Link Output
Second Intelligent Detector
Backplane
RJ45 Serial Link Input RJ45 Serial Link Output
3.3 Termination Panel
With reference to Figure 4 the mounting of both standard equipment and optional equipment
to a Controller is achieved using Termination Panels. One Termination Panel is fitted to the
1.5KVA 8ph wired version of the ST950 and two are fitted to the 3.0KVA 24ph wired version
of the ST950 controller. The Termination Panels do not need to be ordered separately as
they are contained within the Outercase, selected from Table 1. When upgrading a controller
from 1.5KVA to 3.0KVA Configuration Engineers should consult the parts listing for
additional Termination Panels. Termination panels will be positioned centrally at the rear of
the ST950 cabinet, one above the other when two panels are fitted. Certain large items have
designated positions within the controller, others are subject to optimisation. For this reason
some items may vary slightly in position, from one controller to another. Termination panels
have stencilled graphics to assist in the positioning of equipment.