Parameter  Range 
Power Supply  Either:  90-264VAC – 120,230V Nominal, 
  50/60Hz ±4% 
Transients  To BS EN50293:2001 
Power Consumption : Base Unit 
48-16 I/O Card 
Maximum 
Configuration 
7W Nominal 
4W Nominal 
Worst case with interfaces fully loaded: 60W 
Power break support times 
without internal battery 
50ms minimum (only when PSU card used) 
Battery support time – Internal battery  Minimum 1 minute – software controlled 
Size  Basic with GSPI cables 
  With one I/O card & GSPI cables 
120mm (W) x 130mm (H) x 250mm (L approx) 
145mm (W) x 130mm (H) x 250mm (L approx) 
Weight  Basic 
  With one I/O board 
1.6 Kg 
1.8 Kg 
Operating Temperature Range  -34°C to +65°C with internal battery 
-34°C to +74°C with external battery 
Operating Humidity Range 
Up to 95% non-condensing 
Material / Finish  Mild steel Zinc plated chassis 
Powder coated aluminium front panels 
Approvals 
Designed to meet the relevant sections of: 
  EN50293 Electromagnetic compatibility. 
Road traffic signal systems 
  EN50556 Road traffic signal systems 
  TR2522A Remote Monitoring and Control 
of Traffic Control Equipment via a 
Telecommunications Network 
  TR2523 – Traffic Control Equipment 
Interfacing Specification 
 CE Approved 
 RoHS Compliant 