Installation guide
Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 73 of 84
Version 1 Status Issued
Last Editor Carl Rabe Date 11-Dec-2014
Document Name Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
Appendix A Technical Specification
Inbuilt modes of operation
MOVA (Implements MOVA 7) (Licensed option)
UTMC OTU (Licensed option)
Communications
Two 10/100 Ethernet interfaces
Four USB host ports
One USB device port (USB Handset)
One RS232 Auxiliary port
One RS232 TR2523 port
Inputs and outputs
Switchable 24V / 1A protected modem power output [CPU Board]
External DC power supply input [PSU board]
External battery backup input [PSU board]
LV or ELV lamp supply monitor input [PSU board]
All I/O compliant to TR2523
Digital inputs: 8, Isolated changeover relay outputs: 2 [PSU board]
Digital inputs: 48, Isolated changeover relay outputs: 16 [Each 48-16 I/O board]
Maximum number of I/O cards: 3
Maximum number of inputs: 152
Maximum number of isolated digital outputs: 50
Other facilities
Timing sources: Internal Crystal, NTP network time server
Licensed options use encrypted Smart Card
Web based user interface
USB Handset port or optional adaptor for RS232 25 Way D Connector