Installation guide

Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 61 of 84
Version 1 Status Issued
Last Editor Carl Rabe Date 11-Dec-2014
Document Name Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
and MOVA based on the CSV file exported from the UTC instation. Refer to the MOVA 7
Handbook 667/HB/46000/003 for details.
5.13 Observing LEDs
CPU Card
LED State Description
System
(Green)
Slow flash Normal operation.
Medium flash Normal operation, Fault present.
Very fast flash Restricted mode*
COMMS
Communications
(Green)
On Under UTC control, pulses off indicate receipt of
messages.
Off Not under UTC control, pulses on indicate receipt of
messages.
BUSY
(Red)
Off Normally off.
Flashing Flashes to indicate the system is busy performing an
operation that must not be interrupted, for example
start up, upgrade, USB “memory stick” style interface
is busy. Do not remove USB device or switch off the
outstation while this LED is flashing.
Ethernet
Connectivity
(2x green
inboard)
On / Flashing Indicate activity for the two Ethernet interfaces. Top
and Bottom.
Modem Power
(inboard)
On Indicates that the Modem Power is on.
Off Indicates that the Modem Power is off.
* Restricted mode is similar to safe mode on a PC where the user can access the unit to
examine logs, diagnose problems and perform firmware updates.
Table 27 – CPU Board LED States