Controller 
Type 
Lamp Supply Wiring Location  Controller 
Connector 
Part Number 
Microsense 
MPC Midi 
Case/ 
Puffin 
Variant 
The Pink Wire can 
be connected to 
the “B/D L” 
terminal on the 
controller 
backplane, with the 
black attached to 
one of the “Lamp 
Returns” to the left.
Microsense 
MTC 
OMU Lamp Supply (At the back of the cabinet to the 
right of the MDU, amoungst the LV terminations) 
none 
Microsense 
Sentinel 
Dim/ Bright Sense is available at the back of the 
controller cabinet in the LV Terminations section. 
none 
Telent 
Optima 
Dim/ Bright Sense is available at the back of the 
controller cabinet in the LV Terminations section. 
none 
Peek TLC2  The Bright/Dim supply is available at "Lamp1" and 
"Lamp2" terminals on the inner left hand side 
termination panel. 
Neutral is available at the regulatory sign neutral on the 
lower terminal strip at the base ofthe cabinet. 
none 
Peek TSC3
The Bright/Dim supply is available at “Phase1", 
"Phase2" and “N” terminals underneath the main 
cabinet isolator. 
none 
Peek TSP  Lamp supply voltager available on single pin connector 
adjacent to C63 
Peek TSP Mod Kit 
81-669 
Peek TRX  LSM Module Pin 2 can be used for the Lamp supply 
Reference 
Peek 
PTC-1 
The Bright/Dim supply is available at “LVS1” or "LVS2", 
only one of these lamp supplies can be monitored so 
it’s recommended to monitor the 240V Supply on a 
multi supply installation. 
Terminal for 
Pink Lamp 
supply sense