Controller
Type
Lamp Supply Wiring Location Controller
Connector
Part Number
ST900ELV
ST950ELV
HPU: -48V PL8 Pin 2 (Marked -)
0V PL8 Pin 1 (Marked +)
531/4/03187/000
Siemens
T500
The pink wire can be connected to TBB2 on the MPM
(Main Processor Module) and the black to TBB1
none
Siemens
T400
Connect to the lamp supply “Hedgehog” using a spade
connector
Use ¼" spade
crimps
Microsense
MPC
Pelican
Variant
This requires this
connection for the
pink wire to be
soldered directly
onto the
backplane.
The black wire can
be attached to any
of the Lamp
Return Neutrals.
Note: There is
another similar
backplane that
uses ribbon
connections
instead of
terminals (for Midi
Cabinets), this has
the same solder
point available for
Lamp supply
connection.
Solder
point for
Lamp
Supply
Pink