Installation guide

Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 57 of 84
Version 1 Status Issued
Last Editor Carl Rabe Date 11-Dec-2014
Document Name Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
Pin Function
1
+24V DC input – Power for CPU board
when no PSU board is used
2 0V
3
Switched 24V (Nominal) Modem supply
output *
4 Optional RTC supply input
Table 26 – 4 Way 3.81mm pitch – Modem power and DC Power
* Note that the modem supply will follow the battery backup supply during a
mains failure. This output can range from 8 – 28V DC.
5.9 Lamp Supply
The supplied lamp supply cable assembly 667/1/47177/000 should be wired to a suitable
position within the controller. For Siemens controllers the following lamp supply pickup
positions are available. The Controller lamp supply connector mating half will be required
as shown in the table below.
Controller
Type
Lamp Supply Wiring Location Controller
Connector
Part Number
ST700
ST750
Phase Driver: L SK2 pin 6
/ PSU N SK2 pin 7,SK1 pins 1-7
No Connector
required
Connector already
present
ST800
ST900
ST950
MDU: L PL2 8z, 6d
N PL2 20z, 24z, 28z
N PL2 22d, 26d, 30d
Use ¼" spade
crimps
Neutral may need
to come from
controller back
panel
ST750ELV Backplane: -48V PL12 Pin 4
0V PL12 Pin 3
Use Dedicated Kit
667/1/47178/000