Pin  Function 
1 
+24V DC input – Power for CPU board 
when no PSU board is used 
2  0V 
3 
Switched 24V (Nominal) Modem supply 
output * 
4  Optional RTC supply input 
Table 26 – 4 Way 3.81mm pitch – Modem power and DC Power 
* Note that the modem supply will follow the battery backup supply during a 
mains failure. This output can range from 8 – 28V DC. 
5.9  Lamp Supply 
The supplied lamp supply cable assembly 667/1/47177/000 should be wired to a suitable 
position within the controller. For Siemens controllers the following lamp supply pickup 
positions are available. The Controller lamp supply connector mating half will be required 
as shown in the table below. 
Controller 
Type 
Lamp Supply Wiring Location  Controller 
Connector 
Part Number 
ST700 
ST750 
Phase Driver: L  SK2 pin 6 
/ PSU  N  SK2 pin 7,SK1 pins 1-7 
No Connector 
required 
Connector already 
present 
ST800 
ST900 
ST950 
MDU:  L PL2 8z, 6d 
  N PL2 20z, 24z, 28z 
  N PL2 22d, 26d, 30d 
Use ¼" spade 
crimps 
Neutral may need 
to come from 
controller back 
panel 
ST750ELV  Backplane:  -48V PL12 Pin 4 
  0V PL12 Pin 3 
Use Dedicated Kit 
667/1/47178/000 