4.6  The PSU Board 
The PSU board provides power for the system and provides application specific hardware 
modules to support specific functions. This board acts as a GSPI device to allow the CPU 
board to communicate with it. 
The main functions of the PSU Board are: 
  Logic rail power supplies 
  Basic 8 input + 2 output TR2523 I/O 
  Mains monitoring and Zero Cross Over timer (ZXO) 
  Lamp Supply voltage monitoring (ELV & LV) 
  Backup battery control – charging, health, safety 
Figure 6 – PSU Board 
Figure 7 – PSU Board Layout 
Note: This board is shown with the 'front' on the right as it is mounted back to back with 
the CPU board. 
F2
Batt. Fuse
F1
24V I/O Fuse