Description Connector
1 2 x GSPI Bus master to GSPI Peripherals Double RJ45
2 Modem Power
See Table 6 for pinout
4 way 3.81mm pitch Phoenix
3 2 x USB Host Ports (rear) Double USB Type A
4 2 x 10/100 Ethernet Ports
(1
st
port is closest to PCB)
Double RJ45
5 RS232 Port TR2523 16 way IDC boxed header
6 RS232 Port Modem, GPS etc 10 way IDC boxed header
7 USB Handset Port USB Type B
8 2 x USB Host Ports (front) Double USB Type A
Table 5 – CPU Board Connector Functions and Types
Pin Function
1
+24V DC input Power for CPU board
when no PSU board is used
2 0V
3
Switched 24V (Nominal) Modem supply
output *
4 Optional RTC supply input (3V to 28V DC)
Table 6 – 4 Way 3.81mm pitch – Modem power and DC Power
* Note that the modem supply will follow the battery backup supply during a
mains failure. This output can range from 8 – 28V DC
For more information on supported communications devices and connection,
please refer to the IP Router Installation Guide 667/CI/45025/000.