2.3.1 Semi-Integral Interface to Controller
Figure 1 Typical Semi-Integral Stratos Outstation Connectivity
The following data is transferred between the controller and the outstation via RS232
serial cable.
UTC control and reply signals (stage force, confirm etc) as configured by IC4
MOVA stage forces and confirms as configured by IC4
Selected controller detector states as configured by IC4, for use as UTC SCOOT
detectors and MOVA detectors
Faults, for display on outstation fault table
Controller Log, for display on outstation web interface *
1
IC4 configuration upload *
2
Remote handset text
* 1 - When interfacing to an ST950 controller, the controller log transferred to the
outstation is a sub-set of the full log. The web interface on the ST950 should be accessed
directly to examine the controller log details.
* 2 - When interfacing to an ST950 controller, the IC4 configuration file is not transferred
to the outstation. The web interface on the ST950 should be accessed directly to upload
the IC4 configuration.
A dedicated input is provided for the controller lamp supply voltage (see section 3.7).