2.3.1 Semi-Integral Interface to Controller 
Figure 1 – Typical Semi-Integral Stratos Outstation Connectivity 
The following data is transferred between the controller and the outstation via RS232 
serial cable. 
  UTC control and reply signals (stage force, confirm etc) as configured by IC4 
  MOVA stage forces and confirms as configured by IC4 
  Selected controller detector states as configured by IC4, for use as UTC SCOOT 
detectors and MOVA detectors 
  Faults, for display on outstation fault table 
  Controller Log, for display on outstation web interface *
1
  IC4 configuration upload *
2
  Remote handset text 
* 1 - When interfacing to an ST950 controller, the controller log transferred to the 
outstation is a sub-set of the full log. The web interface on the ST950 should be accessed 
directly to examine the controller log details. 
* 2 - When interfacing to an ST950 controller, the IC4 configuration file is not transferred 
to the outstation. The web interface on the ST950 should be accessed directly to upload 
the IC4 configuration. 
A dedicated input is provided for the controller lamp supply voltage (see section 3.7). 