Specifications
Siemens Mobility, Traffic Solutions
Sopers Lane, Poole, Dorset
BH17 7ER
Version 10 Page 94 of 120 Status Issued
Last Editor harry.smyth Date 03 November 2014
Document
Name
GENERAL HANDBOOK FOR HEIMDALL
DETECTORS
Doc. No.
667/HB/31900/000
Copyright Siemens plc 2014 All Rights Reserved
DESCRIPTION AND REMARKS
DMH
DMH:<
D
etector
M
ounting
H
eight, 0 to 2>
DMH=0: Mounting Height #1 (<4.5m) (default)
DMH=1: Mounting Height #2 (4.5 to 6.5m),
DMH=2: Mounting Height #3 (>6.5m)
Note: Applicable to SCOOT Detector only
2
IND
IND:<Detector Output
Ind
ication, 0 to 2>
IND=0 LED indicates detector output (default)
IND=1 LED permanently off
IND=2 LED indicates detector output for 20 minutes after power
applied.
2
LST
LST:<
L
ow
S
peed
T
hreshold, 0 to 1>
LST=0: 8.5 Km/h (default)
LST=1: 4.0 Km/h
N.B. Applicable to both Standard and Single Lane Vehicle
Detectors
2
MPT
MPT:<
M
aximum
P
resence
T
ime, x,y>
x,y is the time in minutes and seconds after which the detector will
return to the ‘in-active’ state even though the vehicle may still be
present. (x – time in minutes, 0 to 255; y – time in seconds, 0 to 59).
Default is x= 5, y = 0. i.e. 5 minutes recovery time.
N.B. Applicable to SCOOT and Stop Line Detectors only.
2
MVA
MVA:<
M
oving
V
ehicle
A
lgorithm, 0 to 1>
MVA=0: Movement and Static Detection Algorithm
MVA=1: Static Detection Algorithm (default)
N.B. Applicable to Stop Line Detectors only.
2
RGE
RGE:<Detection
R
an
ge
, 0 to 1>
RGE=0: Full Range (default)
RGE=1: Reduced Range
N.B. Applicable to Standard and Single Lane Vehicle Detectors
only.
2
SDA
SDA:<
S
peed
D
etector De
a
ctivation Period, 0 to 5000>
Number of milliseconds after detector activation before the detector
output is permitted to return to the ‘active’ state.
Default is 0 mS.
N.B. Applicable to Speed Detectors only.
2