Specifications
Siemens Mobility, Traffic Solutions
Sopers Lane, Poole, Dorset
BH17 7ER
Version 10 Page 88 of 120 Status Issued
Last Editor harry.smyth Date 03 November 2014
Document
Name
GENERAL HANDBOOK FOR HEIMDALL
DETECTORS
Doc. No.
667/HB/31900/000
Copyright Siemens plc 2014 All Rights Reserved
7.6 Terminal Displays
In addition to the ‘static’ displays described so far, the detector may be continuously
updating some outputs.
For example, entering ‘SPD’ displays the current speed of the vehicle being detected:
Keystrokes
Display
Comment
SPD
SPD:45
First vehicle
SPD:40
Second vehicle
SPD:33
Third vehicle
...
...
Although not clear from the above diagram, the new display will appear on the same
line as the original, thus overwriting the old display, and not on the following line as the
diagram may imply.
Note: Functions that have data changes which occur more often than once a
second may not be accurately reflected on the terminal display. For example, if
‘DOS’ is used to display detector activations, then very short activations
(<200mS) may not appear on the terminal display.
7.6.1 SieCom Implementation
The user may find they are using the Siemens SieCom interface connection with either
a cable connection or a wireless link. In both cases, if a continuous updated is required
the command ‘POLL’1 must precede the updateable command.
For example; ‘POLL DOS’ will provide a continuous updated display of the detector
output condition.
1
This is a function of the Siecom terminal interface not the detector unit. If terminal connection is made
via a normal terminal unit (e.g. hyperterminal), then the ‘POLL’ command will not be required.