Specifications

Siemens Mobility, Traffic Solutions
Sopers Lane, Poole, Dorset
BH17 7ER
Version 10 Page 79 of 120 Status Issued
Last Editor harry.smyth Date 03 November 2014
Document
Name
GENERAL HANDBOOK FOR HEIMDALL
DETECTORS
Doc. No.
667/HB/31900/000
Copyright Siemens plc 2014 All Rights Reserved
6.2 Final Commissioning Procedures
Power is applied to the unit and the operation of the detector observed by looking at the
output from the indicator LED which is visible on the side door. If necessary, adjustment
can be made to the alignment by:
(1) ‘Slackening off’ the mounting nut slightly,
(2) Making the minor adjustment whilst, at the same time, observing the detector
operation by looking at the LED;
(3) Re-tighten the mounting nut.
The controller’s input status should then be checked to ensure the detector signal is
connected as required.
Ensure the detector configuration access door is replaced correctly. Refer to
appropriate detector specification (reference 5).