5.7.5 Side Access Configuration Dip Switch Settings
Note: Default settings are with all DIP switches set to ‘0’/ OFF.
Configuration
DIP Switch Number
1 2 3 4 5 6 7 8
Vehicle Filter
0 = Enabled
1 = Disabled
Not
Used
Detector LED
0,0 = Normal Detector O/P
0,1 = Permanently Off
1,0 = Detector O/P for 20
minutes after power applied
1,1 = Normal Detector O/P
Recalibration
Toggle switch (0-
1-0).
Detection
Length
0 = Normal
1 = Reduced
Controls the
effective range
of the detector.
DFM
0 = Default monitor time
(20 hours inactivity)
1 = ‘fault monitor time’ is set by the
Engineer’s Terminal
Remote
Configuration
0 = Disabled
1 = Enabled
Note: Some DIP switches may be marked with ON/OFF. For the purposes of definition, OFF is equal to 0 and ON is equal to 1.
Table 5-28 – Pedestrian Kerbside Detector Configuration Switch Settings
Refer to section 6 for detailed information regarding final commissioning.