Specifications
Siemens Mobility, Traffic Solutions
Sopers Lane, Poole, Dorset
BH17 7ER
Version 10 Page 63 of 120 Status Issued
Last Editor harry.smyth Date 03 November 2014
Document
Name
GENERAL HANDBOOK FOR HEIMDALL
DETECTORS
Doc. No.
667/HB/31900/000
Copyright Siemens plc 2014 All Rights Reserved
5.6.4.2 Detector Height
The detector may be mounted at any height between 3.3 and 4m.
5.6.4.3 Detector Angle
The initial installation angle will change depending on the installation height and road
surface angle. However, the detector is aimed towards oncoming pedestrians, at the
centre line of the on crossing area and towards the far side of the carriageway, as shown
in Figure 24 below.
As a starting point the mounting angle may be pre-set to:
25 degrees from horizontal for a 12 m crossing
Figure 23 : Heimdall set to 25 degrees from horizontal
5.6.4.4 Detector Alignment - default
The detector uses a movement detection algorithm. Thus, the detector is aimed towards
oncoming pedestrians, at the centre line of the on crossing area and towards the far side
of the carriageway, as shown in Figure 24 below.
Arrow pointing
to 25 degrees
(One Large &
Two Small
Notches)