5.5.4.3 Detector Angle
The initial installation angle will change depending on the installation height. As a guide
these are listed as:
4m – 50 degrees from horizontal
6m – 75 degrees from horizontal
8m – 85 degrees from horizontal
Reference section 4.7.1 for instructions on how to pre-set mounting angle
5.5.4.4 Detector Angle for Second Lane Detection
The initial installation angle will change depending on the installation height. In order to
maintain a reasonable line-of-sight it is expected that second lane detection will require at
least 6m installation height as a minimum. As a guide these are listed as:
6m – 50 degrees from horizontal
8m – 75 degrees from horizontal
Reference section 4.7.1 for instructions on how to pre-set mounting angle
5.5.4.5 Detector Alignment - Default
The detector default setup uses a static detection algorithm. The detector is aimed
perpendicular to the traffic flow and just below the centre of the carriageway, as shown in
Figure 18 below. To use this installation method, ensure DIP switch 6 is set to ‘0’, or
using the appropriate terminal command ‘DAA’ is set to ‘0’
1
. This is factory default.
For optimum performance, it is recommended that this alignment is used.
Figure 18 – SCOOT and MOVA Detector Installation – Plan View (4m installation – Static
Algorithm)
1
Please read section 4.8 carefully to fully comprehend configuration priority