5.4.4.4 Detector Alignment
The detectors should be ‘aimed’ at a position approximately 1.5 metres from the
associated ‘stop line’, toward oncoming traffic, as shown in Figure 17 below.
Figure 17 – Stop Line Detector Installation – Plan View
5.4.4.5 Maximum Presence Time
The maximum presence time attribute defines the period of continuous detection before
the detector tunes the stationary object and detection returns to normal. The default
setting is for a period of 4 minutes. However if adjustment is required, DIP switch 5 can
set the maximum presence time to 30 minutes. Alternatively, if a user defined value is
required, the terminal command MPT can be set to the user defined variable (reference
section 7.7.4).
5.4.4.6 Detection Method
The default setting for the detector is such that both static and moving vehicles are
detected. However, the user may modify the detector so that moving vehicles are filtered
from the detection output. This setting can be modified using DIP switch 5 or by using the
terminal command MVA (reference section 7.7.4).
5.4.4.7 Detector Fault Monitor (DFM)
The detector has a fault monitor function. In the default mode, the detector will generate a
fault output (equivalent to a permanent detect) if the detector has not registered an
activation for a period of twenty hours.
This duration can be adjusted to a user defined value by setting DIP Switch 7 to ‘1’ (On)
and then using the terminal command DFM (reference section 7.7.4).