Specifications
Siemens Mobility, Traffic Solutions
Sopers Lane, Poole, Dorset
BH17 7ER
Version 10 Page 50 of 120 Status Issued
Last Editor harry.smyth Date 03 November 2014
Document
Name
GENERAL HANDBOOK FOR HEIMDALL
DETECTORS
Doc. No.
667/HB/31900/000
Copyright Siemens plc 2014 All Rights Reserved
5.4 Stop Line Presence Detector
5.4.1 Performance Details
Operating Range: 3m from the stop line
Lane Width: Typically 3.5m
Vehicle Approach Speed: 0 km/h (0 mph) to 112 km/h (70 mph)1
Detection Presence Time: 1 to 30 minutes (default 4 minutes)
Detector Location: Normally located on the ‘nearside’ road position or
alternatively on the ‘off-side’ primary signal pole.
Detector Mounting Height: 3.3m to 4.0m.
Accuracy: >98% accuracy on vehicle count
LED Orientation: Facing Backwards (reference section 2.3)
5.4.2 Part Number
667/1/31900/03X
Where X is;
0 Basic Detector
1
Basic Detector with RS485 (SiTOS) Serial
Interface
2
2 Basic Detector with Wireless Link Interface
3
3
Basic Detector with a Second Solid-State Relay
Output
4
4
Basic Detector with both a Wireless Link and a
Second Solid-State Relay Output
5
Table 5-13 – Heimdall Stop Line Presence Detector Part Number
1
Subject to configuration (Dip switch #2 –ref Table 5-16)
2
This option is non-standard. Please refer to Siemens Poole for further ordering information.
3
This option is non-standard. Please refer to Siemens Poole for further ordering information.
4
This option is non-standard. Please refer to Siemens Poole for further ordering information.
5
This option is non-standard. Please refer to Siemens Poole for further ordering information.