5.1.5 Side Access Configuration Dip Switch Settings
Note: Default settings are with all DIP switches set to ‘0’/ OFF.
Configuration DIP Switch Number
1 2 3 4 5 6 7 8
Detection Direction
0,0 = Detects vehicles moving towards
unit (default)
0,1 = Detects vehicles moving away from
unit
1,0 = Detects vehicles moving in both
directions (single O/P)
1,1 = Detects vehicles moving in both
directions (dual O/P)
1
Detector LED
0,0 = Normal Detector O/P
0,1 = Permanently Off
1,0 = Detector O/P for 20 minutes
after power applied
1,1 = Normal Detector O/P
Detection
Threshold
0 = 8.5 km/h
1 = 4 km/h
Detection Range
0 = Full
1 = Reduced
DFM
0 = Default
monitor time
(20 hours
inactivity)
1 = ‘fault monitor
time’ is set by
the Engineer’s
Terminal
Remote
Configuration
0 = Disabled
1 = Enabled
Note: Some DIP switches may be marked with ON/OFF. For the purposes of definition, OFF is equal to 0 and ON is equal to 1.
Table 5-4 – Standard VA Detector Configuration Switch Settings
Refer to section 5.6 for detailed information regarding final commissioning.
1
This option requires a special I/O board to be fitted. In this dual output mode, detector o/p 1 will detect vehicles moving towards the unit and detector o/p 2 will
detect vehicles moving away.