4.5 Electrical Connections – UK Variant
4.5.1 General
All Heimdall detectors are equipped with a captive lead and standard 9 pin ‘Buccaneer’
connector (see Figure 7).
1
2
3
4
5
6
7
8
9
Figure 7 – Buccaneer Bulkhead Connector (Front View)
The wires from this connector should be terminated in accordance with the details shown
in sections below.
Note 1: Particular attention should be paid to the correct termination of the power
supply wires. The RED wire should be used for the POSITIVE AC/DC supply feed
and the Black wire for the NEGATIVE supply return.
Note 2: When installing this detector with a 24 AC source, please ensure the 24 AC
source is derived from an earthed secondary transformer (as used in standard
traffic installations).
Note 3: When using 24 AC supply, only use battery powered interface equipment
(e.g. laptop, PDA). Do not connect mains powered/connected interface equipment
to the Heimdall series of detectors, as this will cause the detector’s fuse to fail.
Note 4: When installing this detector with a Siemens ELV controller or a Siemens
ELV controller additional supply, please ensure the RED wire of the interface cable
is connected to the POSITIVE (common) connector, the BLACK wire is connected
to the NEGATIVE (-24VDC) source and the GREEN (screen), if included, is
connected to the POSITIVE (common) connector.
Figure 8 – ELV Detector Power Connections