User`s manual

Wall or Rack Mounting Installation
Instructions
The Advance Network Gateway Unit (ANG_EN) should be:
Installed in a location that is free from shock and vibration.
Protected from direct sunlight and extremes of temperature.
It is recommended that the ANG_EN be mounted within a shelter.
This prevents ANG_EN from being exposed to outside
environmental conditions.
Package
Configurations
The ANG_EN is available in three models;
Wall mount unit
19-inch rack unit
Zone 1 wall mount.
Wall Mounting
The mounting wall must be capable of supporting the weight of the
ANG_EN; see Chapter 1, Specifications and Figures 1-2 through 1-4.
Wall Mount Unit: Use four, 5/16-inch (M8) or 3/8-inch (M10) lag bolts to
mount the ANG_EN to the wall. Mounting bolts must be secured to solid
wall construction members such as studs and into the wall only. Allow
adequate clearance on the left side to allow the door to swing open.
Zone 1 Wall Mount Unit: Use four, ¾ inch (M20) lag bolts to mount the
NAU to the wall. Mounting bolts must be secured to solid wall
construction members such as studs and into the wall only.
Optional Conduit
Connection Box
If your wall mounted unit has a Conduit Connection box, holes must be
drilled into the side or bottom of the box to accommodate the moisture
protected.
14 Installation 2000590-001