User`s manual
2000591-001 Command Summary •• 65
Command Summary, Continued
Enter the list command at any time from the Configuration Management
interface to see event buffer messages. The list command has an inter-
nal current sequence number that is set to 1 each time a Configuration
Management login occurs. The list command will show 10 messages
each time it is entered, beginning with the current sequence number. The
current sequence number is updated each time list is used. A new cur-
rent sequence number can be entered with the list command:
local> list 155
msg | source | destination | size | source port | time stamp
155 | Trace enabled | 00:01:48.23
156 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:01:48.29
157 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:01:49.00
158 | IP-172.16.9.210 | IP-172.16.9.211 | 64 | Ethernet | 00:01:49.75
159 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:01:50.11
160 | Station detected IP-172.16.9.014 | 00:02:00.00
161 | IP-172.16.9.014 | IP-172.16.9.210 | 1536 | 5 | 00:02:18.29
162 | IP-172.16.9.211 | IP-172.16.9.210 | 1536 | 2 | 00:02:18.00
163 | IP-172.16.9.210 | IP-172.16.9.211 | 1132 | Ethernet | 00:02:19.75
164 | IP-172.16.9.211 | IP-172.16.9.210 | 64 | 2 | 00:02:20.11
The event display gives a time-stamp, and an event description. All
events other than frame-capture events are always shown as single
lines. Captured frames may be summarized as single lines, or expanded
into a multi-line display.
Time stamps are shown as elapsed time from the last board reset or
power-on.
The user can view more than 22 messages by supplying a sequence
number and list length:
list 1, 300 List message numbers 1 – 300.
The list length may appear by itself:
list , 32
This lists the next 32 trace buffer entries, and increments the current
message number by 32.
All the messages in the internal trace buffer can be viewed by listing se-
quence number one then entering the list command until the last mes-
sage is displayed. When the current message number is incremented to
the last message in the internal buffer, it is automatically set to 1.
list