User`s manual
16 •• Installation 2000591-001
Wall or Rack Mounting Installation
The Advance Network Gateway (ANG) should be:
• Installed in a location that is free from shock and vibration.
• Protected from direct sunlight and extremes of temperature.
• It is recommended that the unit be mounted within a shelter. This
prevents it from being exposed to outside environmental conditions.
The unit is designed for standard wall or Zone 1 wall installations, or 19-
inch rack installations; see Chapter 1. Figures 1-2, 1-3, and 1-4. Shown
below is a typical wall mount installation for NEC Division 2 or non-rated
areas.
The mounting wall must be capable of supporting the weight of the unit;
see Chapter 1., ANG_DN Specifications and Figures 1-3 and 1-4.
Wall Mount Installation: Use four, 5/16-inch (M8) or 3/8-inch (M10) lag
bolts to mount the unit to the wall. Mounting bolts must be secured to
solid wall construction members such as studs and into the wall only.
Allow adequate clearance on the left side to allow the door to swing
open.
Zone 1 Wall Mount Installation: Use four, ¾-inch (M20) lag bolts to
mount the NAU to the wall. Mounting bolts must be secured to solid wall
construction members such as studs and into the wall only.