Troubleshooting guide
Optiset E Option Modules 2-7
2. Optiset E Option
Modules
To complete in-
stallation of the
Analog Adapter
➩
Connect an analog terminal to the 6-pin
port on the back of the Analog Adapter
(connecting tip/ring to pins 3 and 4).
➩
Reconnect the phone line to the phone.
Note:
The Analog Adapter requires the Optiset E Local Power
Supply for operation. (See “Optiset E Local Power Supply” on
page 2-14.)
To complete in-
stallation of the
Control Adapter
➩
Connect the personal computer to the 9-pin
(RS-232) connector on the back of the
Control Adapter.
➩
Connect the electret-style headset to the
RJ8 connector on the adapter.
➩
Reconnect the phone line to the phone.
To complete in-
stallation of the
Data Adapter
➩
Connect the data terminal equipment to the
25-pin (RS232) connector on the back of
the Data Adapter.
➩
Reconnect the phone line to the phone.
To complete in-
stallation of the
Headset Adapter
➩
Connect the headset(s) to the headset (RJ8)
connector(s) on the adapter.
➩
Reconnect the phone line to the phone.
To complete in-
stallation of the
Headset Plus
adapter
➩
Connect the headset(s) to the headset (RJ8)
connector(s) on the adapter.
➩
Connect the recorder to the recorder (RJ11)
connector.
➩
Reconnect the phone line to the phone.