Troubleshooting guide

Optiset E Option Modules 2-7
2. Optiset E Option
Modules
To complete in-
stallation of the
Analog Adapter
Connect an analog terminal to the 6-pin
port on the back of the Analog Adapter
(connecting tip/ring to pins 3 and 4).
Reconnect the phone line to the phone.
Note:
The Analog Adapter requires the Optiset E Local Power
Supply for operation. (See “Optiset E Local Power Supply” on
page 2-14.)
To complete in-
stallation of the
Control Adapter
Connect the personal computer to the 9-pin
(RS-232) connector on the back of the
Control Adapter.
Connect the electret-style headset to the
RJ8 connector on the adapter.
Reconnect the phone line to the phone.
To complete in-
stallation of the
Data Adapter
Connect the data terminal equipment to the
25-pin (RS232) connector on the back of
the Data Adapter.
Reconnect the phone line to the phone.
To complete in-
stallation of the
Headset Adapter
Connect the headset(s) to the headset (RJ8)
connector(s) on the adapter.
Reconnect the phone line to the phone.
To complete in-
stallation of the
Headset Plus
adapter
Connect the headset(s) to the headset (RJ8)
connector(s) on the adapter.
Connect the recorder to the recorder (RJ11)
connector.
Reconnect the phone line to the phone.