User Manual
12
Threaded globe valves
Typical applications Actuators Data sheet 5.5 mm
– Floor heating
– Chilled ceilings
– VAV
– Fan coil units
– Zone control
SSB.. N4891 200 N
200 N
Operating voltage
Positioning
signal
Positioning
time [s]
Auxiliary switch
SSB..1.1
AC 230 V 3-position 150
ü
SSB31 SSB31.1
AC 24 V 3-position 150
ü
SSB81 SSB81.1
AC/DC 24 V 0...10 V 75 – SSB61 –
PN 16 1…110 °C
DN
G
[Inch]
k
vs
[m
3
/h]
∆p
s
[kPa]
∆p
max
[kPa]
∆p
s
[kPa]
∆p
max
[kPa]
∆p
s
[kPa]
∆p
max
[kPa]
Data sheet
N4847
VVP47.10-..
1)
10 G ½B 0.25 / 0.4 700 400 1000 400 1000 400
VVP47.10-..
10 G ½B 0.63 / 1 250 250 500 400 500 400
VVP47.10-1.6
10 G ½B 1.6 150 150 300 300 300 300
VVP47.15-2.5
15 G ¾B 2.5 150 150 300 300 300 300
VVP47.20-4
20 G 1B 4 100 100 175 175 175 175
VXP47.10-..
10 G ½B 0.25 / 0.4 – 400 – 400 – 400
VXP47.10-..
10 G ½B 0.63 / 1 – 250 – 400 – 400
VXP47.10-1.6
10 G ½B 1.6 – 150 – 300 – 300
VXP47.15-2.5
15 G ¾B 2.5 – 150 – 300 – 300
VXP47.20-4
20 G 1B 4 – 100 – 175 – 175
VMP47.10-..
10 G ½B 0.25 / 0.4 – 400 – 400 – 400
VMP47.10-..
10 G ½B 0.63 / 1 – 250 – 400 – 400
VMP47.10-1.6
10 G ½B 1.6 – 150 – 300 – 300
VMP47.15-2.5
15 G ¾B 2.5 – 150 – 300 – 300
Union nuts for threaded valves
Union nuts for threaded valves See page 14
Typical applications
Actuators
Data sheet 4.5 mm 2.5 mm
– Chilled ceilings
– VAV
– Fan coil units
STP..
SFP..
SSP..
N4884
N4865
N4864
100 N
135 N 160 N
Operating voltage
Positioning
signal
Positioning
time [s]
Spring return
function [s]
AC 230 V
2-position 210 – STP23 – –
2-position 10 30...50 – SFP21/18 –
3-position 150 – – – SSP31
AC 24 V
2-position 10 30...50 – SFP71/18 –
3-position 43 – – – SSP81.04
3-position 150 – – – SSP81
0…10 V 270
2)
– STP63 – –
AC/DC 24 V
2-position/PDM 270 – STP73 – –
0...10 V 34 – – – SSP61
PN 16 1…110 °C
DN
G
[Inch]
k
vs
[m
3
/h]
∆p
s
[kPa]
∆p
max
[kPa]
∆p
s
[kPa]
∆p
max
[kPa]
Data sheet
N4845
VVP45.10-..
1)
10 G ½B 0.25 / 0.4 / 0.63 / 1 / 1.6 725 400 725 400
VVP45.15-2.5 15 G ¾B 2.5 350 350 350 350
VVP45.20-4 20 G 1B 4 350 350 350 350
VVP45.25-6.3 25 G 1¼B 6.3 300 300 300 300
VXP45.10-.. 10 G ½B 0.25 / 0.4 / 0.63 / 1 / 1.6 – 400 – 400
VXP45.15-2.5 15 G ¾B 2.5 – 350 – 350
VXP45.20-4 20 G 1B 4 – 350 – 350
VXP45.25-6.3 25 G 1¼B 6.3 – 300 – 300
VMP45.10-.. 10 G ½B 0.25 / 0.4 / 0.63 / 1 – 400 – 400
VMP45.10-1.6 10 G ½B 1.6 – 400 – 400
VMP45.15-2.5 15 G ¾B 2.5 – 350 – 350
VMP45.20-4 20 G 1B 4 – 350 – 350
VVP45..N with Serto compression ttings, k
vs
= 2.5 / 4 / 6.3 m³/h
VVP45..S, VMP45..S with Conex® compression ttings, k
vs
= 0.63 / 1 / 1.6 / 2.5 m³/h
VVP47..S, VMP47..S with Conex® compression ttings, k
vs
= 0.63 / 1 / 1.6 / 2.5 m³/h
1)
.. = k
vs
value
2)
In control mode (warm-up time) min. running time approx. 30 s/mm